ALARM SYSTEM FOR OIL WATER SEPARATOR- KAH050

ATEX model for decanter and hydrocarbon separator

image du ALARM SYSTEM FOR OIL WATER SEPARATOR- KAH050

Control device associated with decanters and hydrocarbon separators

Avantages :

  • Compliance: ATEX hydrocarbon detection alarm system complies with the requirements of EN 858-1 and 2 standards for light liquid separators
  • Reliability: the KAH050 alarm system allows: - to alert the operator in case of saturation of the device - limit maintenance frequencies and pumping costs
  • Modularity: the case can accommodate up to 3 probes, and comes with a hydrocarbon probe including 10 ml of cable for zone 0.
  • Signalling: audible and optical alarm
  • Functionality: 3 contact relay outputs

En bref

En détails

Dimensionnement

En pratique

Vidéos

Taille :

Application :

The KAH050 alarm is a device associated with pre-treatment systems (decanters and hydrocarbon separators) that ensures the optimal operation of the system by a level control system

Conception :

  • IP 65 polycarbonate control unit for wall mounting. Power supply 230 V AC - 9 VA - 50 Hz. Dimensions (WxHxD): 240 x 120 x 70 mm
  • ATEX certification: Control unit certified BVS 07 ATEX E 090 to be installed in a non-hazardous zone, associated with the BVS 07 ATEX E 091 X certified hydrocarbon probe that can be installed in zone 0
  • Signaling by 6 LEDs (operation and alarm)
  • Built-in audible alarm (deactivable)
  • Buttons on the front of the enclosure for testing and reset of the alarm
  • PE/Stainless steel hydrocarbon layer detection probe, IP 68, based on high-frequency capacitive measurement, with cable length 10 meters (maximum length: 300 m)
  • 3 relay output, 230 V AC, 3A, potential-free inverter contacts

Fonctionnement :

The KAH050 alarm system triggers an optical and audible signal as soon as the layer of hydrocarbons (sludge or high level depending on the options chosen), present in the decanter or separator, reaches the upper part of the probe. Its positioning depends on the retention volume of the separator. It indicates when to empty or clean the separator. The control box to be installed outside the ATEX zone and its probe comply with the ATEX directive 94/9/EG.

Options :

  • Oil level additionnal sensor - SEP0202
  • Sludge level additionnal sensor - SEP0203
  • Water level additionnal sensor- SEP0204
  • On site assistance (px/day)
  • Box support - SEP1000
  • Shielded cable of section 2x1 mm² - KCABLE
  • ATEX Sensor Cable Extender - SEP0207
Référence DN X (mm) Y (mm) Z (mm) H (mm) B (mm) C (mm) S (mm) Nbre de tours Couple maxi Nm Poids (kg)
VMP800 800 1000 1947 155 1847 1100 1861 99 170 36 118
VMP1000 1000 1200 2341 175 2241 1300 2255 103 175 65 180
VMP1200 1200 1400 2805 179 2705 1500 2715 108 208 110 228
VMP1500 1500 1850 3400 256 3300 1900 3310 122 221 195 410