DOHR

FRANCE
Horizontal storm water overflow system
side threshold
Control of the restored flow and management of peak flows while respecting the network hydraulics

Avantages

  • Compactness : optimised design through high-performance and
    well-dimensioned internal equipment

  • High performance : built-in flow control, dimensioned to prevent any
    overflow as long as the nominal flow rate has not been reached

  • Adaptability : tailored design making it possible to consider many
    configurations with networks up to DN 1200 mm

  • Easy to implement : equipement are delivered set and regulated in our factory, ready-to-install

  • Equipement particularly suitable for long discharging blades

  • 10-year warranty via insurance supplemented by an Epers

Télécharger la fiche Demande d'informations
DOHR

Taille : Sizing upon request

Application

Structure intended to control the flow rate towards the treatment and
to manage excess flows via overflow on rainwater or combined
networks

Descriptif

Regulated flow storm weir including a FLOREG or REGULO type flow regulator and an outlet blade respecting the hydraulics of the water system.

Conception

  • Made from S235 steel assembled on flat bottoms, protected
    after SA 2.5 sanding according to ISO 8501-1 with a hot
    polymerised polyurethane coating 500 µm thick

  • Flow rate controller made from 304L stainless steel, FLOREG or REGULO device

  • Headwater dimensioned to remove the peak flow rate in
    compliance with the hydraulics of the water network

Fonctionnement

Controlled flow storm water overflow of the DOHR type is designed and
dimensioned for a perfect control of the flow rate to treatment.
The controlled flow is reached before any overflow. Excess flow rates are managed
by the overflow in compliance with the hydraulics of the network.
Each structure is subject to a hydraulic validation using the data of the project.

Options

  • Overflow screening system - DEGSURVERSE

  • Standardised ladder - ECH

  • Detection of the number of overflows - COMPTEUR

  • Cathodic protection - ANODEINT and ANODEEXT

  • Risers - REH and Buffers - COUV